E-FLASHER
Installation Guide
First and foremost, you must always refer to, and follow, the National Electric Code as well as local codes for proper installation of this product. The following is only a guide to some of the installation requirements. It is the responsibility of the purchaser of this transformer to ensure proper and safe installation, use and maintenance.

1. The E-FLASHER has a minimum load requirement of 2,000vts.  This means the transformer must see a minimum 2,000vt load. Failure to do so can cause damage, or shorten the life and performance of the transformer.

2. Limit overall length of the GTO leads from the transformer to under 6' (six feet). If possible, always try to "reduce" the length to as short as possible.

3. Do not extend the factory GTO leads on the transformer. Always work to mount the transformer as close to the neon as possible to allow the GTO cables to be as short as possible (see following diagram).




















4. Never install the GTO cable into metallic conduit.

5. Never use metal tube supports.

6. Never use metal tie wire on the neon which the tie wire is connected to metal.

7. Keep both factory GTO cables (from the transformer) as close to the same length as possible.

8. Keep all GTO cables a minimum 1" (one inch) away from the transformer. Never run GTO cable next to or on top of the transformer.

9. Do not cross GTO cables.

10. Keep all GTO cables a minimum 1" (one inch) away from any metallic surface.

11. Never overload the transformer. Exceeding the maximum recommended tube length can damage or shorten the life and performance of the transformer. Refer to the below footage chart.

12. This transformer is for INDOOR USE ONLY.

13. This transformer can be mounted directly on a metallic or nonmetallic surface however free air flow should be insured to provide adequate ventilation.

14. If mounting more than one transformer on a sign, mount the transformers away from each other. Be sure to maintain at least 3" (three inches) or more between each unit.

15. Do not mount the transformer on a surface which generates heat.

16. Again, you must always conform to all local and national electric codes when installing.

17. Never modify the power cord in any way. This includes removing or bending the grounding spade on the cord plug-in tip. Never cut off the power cord to hard wire. If you choose
to modify the power cord - the WARRANTY IS VOIDED - NO EXCEPTIONS. If you feel your install
requires the transformer to be hard
wired in, we suggest that you install a
"add-a-tip" (see picture) on the building
power line. This allows you to
plug-in and unplug the transformer as
needed. These are inexpensive and
are readily available at most hardware
stores such as Ace, True Value, Home Depot and Lowes.
Add-A-Tip
Female
Male
***Always DEDUCT 1 foot for each pair of electrodes***
E-FLASHER  FOOTAGE  CHART
Read a great technical article on Electronic Neon Transformers that appeared in the sign industry's
SIGNS OF THE TIMES magazine.
NEON                      ARGON
15mm    13mm    12mm    10mm    8mm
15mm    13mm    12mm    10mm    8mm
35'         31'          28'         23'        15'
42'         35'          33'         27'        15'
***Always DEDUCT 1 foot for each pair of electrodes***
WRONG!
RIGHT!
Keep GTO from
transformer as
short as possible